Steel Mill Accumulator

figureitout-logoYears ago we built the complete hydraulic system for a continuous steel caster at a steel producer. The HPU had a 300-gallon reservoir with 6 pumps each driven by 300-hp motors, as well as a filter and cooling system. There were several very large manifold stands and two large bag-type accumulator assemblies.

Each accumulator stand consisted of ten 20-gallon bag-type accumulators with Viton bags. The hydraulic piping was all interconnected using 2″ socket-welded fittings and 4-bolt O-ring flanges connected to a common manifold. The stands were fabricated to keep the accumulators mounted in the vertical position.

When the fabrication was completed, the stands were pressurized with hydraulic oil to check for weld leaks. After repairing a couple of leaks, the stands were painted, crated, and shipped directly to the job site. The accumulators would be pre-charged at the job site to 1450 psi since shipping regulations required the units to be shipped without any nitrogen pre-charge. Otherwise special permits would be required.

When the hydraulic system was installed and the accumulators pre-charged, we found that eight of the Viton accumulator bags on one stand were faulty and leaked the nitrogen into the hydraulic system, bubbling out through the reservoir.

Any idea what caused the bags to fail?

See the Solution

By Robert Sheaf, CFPAI/AJPP, CFPE, CFPS, CFPECS, CFPMT, CFPMIP, CFPMMH, CFPMIH, CFPMM, CFC Industrial Training

Share this information.

Related Posts

Leave a Reply

Your email address will not be published. Required fields are marked *

Sponsor

Sponsors

Get Our Enews!

Sign up for the FPJ Insider Guide

Sign up to receive fluid power industry news, economic updates, professional development content, and product news delivered right to your inbox.

We will never share your data with a third party without your permission. Adjust your email preferences at any time, and unsubscribing is quick and easy.

Fluid Power Journal Resources